List of Filters

1/5/2011 11:27 AM You can subscribe to this wiki article using an RSS feed reader.
  

Table 1. Olympus Confocal Laser Scanning Microscopes

 

Microscope Illumination Excitation
DM/Filter
PMt1 PMT2 PMT3 Emission
Filter
FV1000
Main scanner
405,
440,
488,
561, 
633 nm
BS 20/80
DM 405/488
DM 405/488/568/633
DM 458/515
DM 405-440/515
DM 405/488/543
Mirror
Glass
SDM560
SDM510
SDM490
 
Mirror
Glass
SDM640
SDM560
BA655-755
BA560-660
BA585-615
BA585-685
 
FV1000 
SIM scanner
405 nm ADM 504/473
ADM 405/488
ADM 450
ADM 515
ADM 559
ADM 720
ADM 650
       
FV1000
Epi illumination
Mercury
75W
BP 400-440
BP 470-490
BP 460-490 (?)
      BA 475
BA 510 IF
BA 510-550
DSU Xenon 
75W (?)
350/50
403/12
490/20
555/28
635/20
      457/50
528/38
617/73
685/40
Gemini
FV1000
Main scanner
405,
440,
488,
515,
559,
635 nm
BS 20/80
DM 405/488
DM 405/488/559
DM 405/488/559/635
DM 458/515
DM 405-440/515
Mirror
Glass
SDM560
SDM510
SDM490
Mirror
Glass
SDM640
SDM560
BA655-755
BA575-675
BA575-620
BA465-495
 
Gemini
FV1000
SIM scanner
405,
440,
488,
515,
559,
635 nm
ADM 405/473
ADM 405/488
ADM 450
ADM 515
ADM 559
ADM 720
RDM 650
       
Gemini
FV1000
Epi illumination
Mercury
75W 
         
Gemini
DSU
Mercury
120W
(X-Cite
120PC)
CFP
FRET
mOrange
mCherry
      CFP (480 nm)
FRET (525 nm)
mOrange (546 nm)
mCherry (546 nm)
Injection
Setup
Xenon
75W (?)
         

* DM = Dichroic mirror

 

* PMT = Photomultiplier tube

Table 2. Bio-Rad Confocal Laser Scanning Microscopes

 

MICROSCOPE ILLUMINATION EXCITATION
DM/FILTER
PMT1 PMT2 PMT3 EMISSION 
FILTER
RTS 2000
Single photon
440, 
488, 
568, 
647 nm

 
560LP (1:528/50, 2/3:open)
525LP (1:500/30)
100% 2/3
500LP(1:450/80, 2/3: open)

Open(2:open, 3:525/50)

650LP (2:605/50, 3:700/75)

560LP(2:525/50, 3:605/70)

DiA/I (2:550/30, 3:650/30)

Open(2:open, 3:525/50)

650LP(2:605/50, 3:700/75)

560LP(2:525/50, 3:605/70)

DiA/I (2:550/30, 3:650/30)

 
RTS 2000
Two photon
780~
920 nm
  the same as above the same as above the same as above  
Radiance 2000
Single photon
442, 
488, 
568, 
637 nm
100% Det1
440 DCLPXR
500 DCLPXR
560 DCLPXR
650 DCLPXR
100% Det 2/3
Blocking Filter:
BGG22
E625SP
HQ460/50
HQ475/40
=========
Emission Filter:
HQ390/70
HQ450/80
D488/10
HQ500LP
HQ515/30
HQ528/50
Blocking Filter:
E525/70
HQ575/150
E625SP
HQ540/50
HQ540/40
========
Emission Filter:
E460LP
HQ515/30
HQ600/40
E570LP
HQ590/70
HQ600/50
E600LP
Blocking Filter:
HQ575/150
HQ630/140M-2P
=======
Emission Filter:
E570LP
HQ590/70
HQ600/50
E600LP
HQ660LP
 
Radiance 2000
Two photon
850~
920 nm
None DM: 
560DCLP
515DCLP
==========
Filter:
ET525/50M-2P
CFP
DM:
None

==========
Filter:
ET620/60M-2P
YFP
   
MRC 1024 488, 
514, 
568, 
647 nm
Triple DM
488/568/647
DM: 560DRLP
==========
605DF32
585EFLP
605DF32
522DF35 680DF32  
MRC 1024
Epi illumination
Xenon
150W
445 (GFP/YFP)
DM510 (GFP, Nikon)
DM580 (Nikon)
CFP (Chroma)
 
      ??
BA520
BA590
??

 

Table 3. Nikon Microscopes

 

MICROSCOPE ILLUMINATION EXCITATION
DM/FILTER
PMT1 PMT2 PMT3 EMISSION 
FILTER
Nikon
RCM 8000
Single photon
[400mW, KrAr,457~675nm]
488 
514 nm (??)
         
Nikon
RCM 8000
Two photon
Two-photon, 
850-920 nm
         
Nikon
RCM 8000
Epi illumination
Mercury
75W
         
Nikon
TE 2000
TIRF/PALM
488, 
568, 
647 nm
         
Nikon
TE 2000
Yokogawa
488, 
568, 
647 nm
         
Nikon
TE 2000
Epi illumination
Mercury
75W